« Previous
Next »
Journal of Cardiovascular Computed Tomography
Volume 1, Issue 1
, Pages 29-37
, July 2007
Usefulness of multislice spiral computed tomography coronary angiography in patients with acute chest pain in the emergency department
References
- . Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol. 2004;43:2265–2270
- . Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation. 2002;106:2051–2054
- . Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003;107:664–666
- . Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J. 2005;26:1482–1487
- . Diagnostic accuracy of non-invasive 64-slice C.T.coronary angiography in patients with stable angina pectoris. Eur Radiol. 2005;1–8
- . Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005;46:552–557
- . Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol. 2004;43:831–839
- . Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography. Radiographics. 2004;24:787–800
- . Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography. J Comput Assist Tomogr. 2003;27:62–69
- . Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates. Int J Cardiovasc Imaging. 2005;1–5
- . Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. AJR Am J Roentgenol. 2002;179:911–916
- . Noninvasive coronary angiography with multislice computed tomography. JAMA. 2005;293:2471–2478
- . ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology. 2001;220:712–717
- . Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging. 2002;26:106–111
- . Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography. AJR Am J Roentgenol. 2005;184:649–654
- . Coronary angiography with multi-slice computed tomography. Lancet. 2001;357:599–603
- . Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain. Eur Radiol. 2004;14:169–177
- . Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol. 2004;44:1230–1237
- . Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient- versus segment-based analysis. Circulation. 2004;110:2638–2643
- . Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol. 2004;39:223–229
- . Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol. 1990;15:827–832
- . A reporting system on patients evaluated for coronary artery disease (Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association). Circulation. 1975;51:5–40
- . High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation. 2005;112:2318–2323
- . Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA. 2006;296:403–411
- . The disease burden associated with overweight and obesity. JAMA. 1999;282:1523–1529
- . Risk factors for non-cardiac chest pain in the community. Aliment Pharmacol Ther. 2005;22:1023–1031
- . Heart disease and stroke statistics--2006 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Circulation. 2006;113:e85–e151
- . Epidemiology of acute coronary syndromes in a Mediterranean country: aims, design and baseline characteristics of the Greek study of acute coronary syndromes (GREECS). BMC Public Health. 2005;5:23
- . ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses. AJR Am J Roentgenol. 2005;184:1413–1419
- . Usefulness of noninvasive MSCT coronary angiography as first-line imaging technique in patients with chest pain: initial clinical experience. Int J Cardiol. 2005;102:469–475
- . The TIMI risk score for unstable angina/non-ST elevation MI: A method for prognostication and therapeutic decision making. JAMA. 2000;284:835–842
- . ACC/AHA 2002 guideline update for exercise testing: summary article (A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines)). J Am Coll Cardiol. 2002;40:1531–1540
Conflict of interest: Dr Flamm reports that he received grant or research support from Siemens Medical Solutions. Dr M. Huber is an employee of Siemens Medical Solutions.
PII: S1934-5925(07)00013-5
doi: 10.1016/j.jcct.2007.04.013
© 2007 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Cardiovascular Computed Tomography
Volume 1, Issue 1
, Pages 29-37
, July 2007
