Journal of Cardiovascular Computed Tomography
Volume 1, Issue 3 , Pages 162-165 , December 2007

Coronary computed tomography angiography: principles of contrast material administration

Received 30 April 2007 ,Accepted 9 August 2007.

References 

  1. Bae KT. Peak contrast enhancement in CT and MR angiography: when does it occur and why? (Pharmocokinetic study in a porcine model). Radiology. 2003;227:809–816
  2. Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT (Part II. Effect of reduced cardiac output in a porcine model). Radiology. 1998;207:657–662
  3. Bae KT. Technical aspects of contrast delivery in advanced CT. Appl Radiol. 2003;32:12–19
  4. Becker CR, Hong C, Knez A, Leber A, Bruening R, Schoepf UF, et al. Optimal contrast application for cardiac 4-detector row computed tomography. Invest Radiol. 2003;38:690–694
  5. Cademartiri F, Mollet NR, Lemos PA, Saia F, Midiri M, de Feyter PJ, et al. Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol. 2006;187:W430–W433
  6. Knollmann F, Schimpf K, Felix R. Iodine delivery rate of different concentrations of iodine-containing contrast agents with rapid injection. Rofo. 2004;176:880–884
  7. Bettman MA. Contrast media: safety, viscosity and volume. Eur Radiol. 2005;15(suppl 4):62–64
  8. Awai K, Inoue M, Yagyu Y, Watanabe M, Sano T, Nin S, et al. Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT. Radiology. 2004;233:682–688
  9. Bae KT. Comparison of moderate versus high concentration of contrast media injected at the same total iodine dose and fixed injection duration. Radiology. 2005;236:740–741
  10. Rist C, Nikolaou K, Kirchin MA, van Gessel R, Bae KT, von Ziegler F, et al. Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per millimeter. Invest Radiol. 2006;41:460–467
  11. Bae KT, Tao C, Gurel S. Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography. Radiology. 2007;242:582–589
  12. Ho LM, Nelson RC, DeLong DM. Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?. Radiology. 2007;243:431–437
  13. Yamamuro M, Tadamura E, Kanao S, Wu W, Tambara K, Komeda M, et al. Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation. J Comput Assist Tomogr. 2007;31:272–280
  14. Cademartiri F, Luccichenti G, Gualerzi M, Gualerzi M, Brambilla L, Brambilla V, et al. Intravenous contrast material administration in multislice computed tomography coronary angiography. Acta Biomed. 2005;76:86–94
  15. Fleishmann D. Use of high concentration contrast media: principles and rationale–vascular district. Eur J Radiol. 2003;45(suppl 1):88–93
  16. Bae KT, Tran HQ, Heiken JP. Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmokinetic analysis and experimental porcine model. Radiology. 2000;16:872–880
  17. Bae KT, Tran HQ, Heiken JP. Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method. Radiology. 2004;231:732–736
  18. Cademartiri F, Luccichenti G, Marano R, Gualerzi M, Brambilla L, Coruzzi P. Comparison of monophasic and biphasic administration of contrast material in non-invasive coronary angiography using a 16-row multislice computed tomography. Radiol Med (Torino). 2004;107:489–496
  19. Vrachliotis TG, Bis KG, Haidary A, Kosuri R, Balasubramaniam M, Gallagher M, et al. Atypical chest pain: coronary, aortic, and pulmonary vasculature enhancement at biphasic single-injection 64-section CT angiography. Radiology. 2007;243:368–376
  20. Cademartiri F, Nieman K, van der Lugt A, Raaijmakers RH, Mollet N, Pattynama PM, et al. Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology. 2004;233:817–823
  21. Johnson TR, Nikolaou K, Wintersperger BJ, Fink C, Rist C, Leber AW, et al. Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest. J Comput Assist Tomogr. 2007;31:265–271
  22. Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin GP. Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr. 2002;26:598–607
  23. Boonn WW, Litt HI, Charagundla SR. Optimizing contrast injection for coronary CT angiography and functional cardiac CT. Appl Radiol. 2007;51–57

 Conflict of interest: Dr. Lin reports no conflict of interest.

PII: S1934-5925(07)00216-X

doi: 10.1016/j.jcct.2007.08.001

Journal of Cardiovascular Computed Tomography
Volume 1, Issue 3 , Pages 162-165 , December 2007