« Previous
Next »
Journal of Cardiovascular Computed Tomography
Volume 2, Issue 6
, Pages 351-359
, November 2008
What makes a coronary CT angiogram nondiagnostic?
References
- . Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005;46:552–557
- . Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy [published online ahead of print February 21, 2008]. Eur Heart J. 2008;29:766–776
- . Indications for coronary and cardiac computed tomographic angiography. Cardiol Rev. 2007;15:87–96
- . Moving beyond grading of coronary arterial stenosis on coronary computed tomographic angiography. J Am Coll Cardiol Imaging. 2008;1:460–471
- . Artifacts in ECG-synchronized MDCT coronary angiography. AJR Am J Roentgenol. 2007;189:581–591
- . Artifacts in CT: recognition and avoidance. Radiographics. 2004;24:1679–1691
- . McNitt-Gray MF: A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms [published online ahead of print August 11, 2005]. Phys Med Biol. 2005;50:3989–4004
- . Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience [published online ahead of print June 4, 2008]. Eur Radiol. 2008;18:2414–2424
- ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging. A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group; American College of Radiology; Society of Cardiovascular Computed Tomography; Society for Cardiovascular Magnetic Resonance; American Society of Nuclear Cardiology; North American Society for Cardiac Imaging; Society for Cardiovascular Angiography and Interventions; Society of Interventional Radiology. J Am Coll Cardiol. 2006;48(7):1475–97.
- . Physics of cardiac imaging with multiple-row detector CT. Radiographics. 2007;27:1495–1509
- . Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol. 2004;39(4):223–229
- . Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr. 2002;26(4):598–607
- . Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique [published online ahead of print October 29, 2004]. Radiology. 2004;233:817–823
- . Right heart: split-bolus injection of diluted contrast medium for visualization at coronary CT angiography [published online ahead of print March 27, 2008]. Radiology. 2008;247:356–364
- . Image-correction techniques in SPECT. Comput Med Imaging Graph. 2001;25(2):117–126
Conflict of interest: Dr. Min serves on the speaker's bureau for GE Healthcare. Dr. Lin reports no conflicts of interest.
PII: S1934-5925(08)00629-1
doi: 10.1016/j.jcct.2008.10.011
© 2008 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Cardiovascular Computed Tomography
Volume 2, Issue 6
, Pages 351-359
, November 2008