Journal of Cardiovascular Computed Tomography
Volume 3, Issue 1 , Pages 45-51, January 2009

How to use a prospective gated technique for cardiac CT

  • James P. Earls, MD

      Affiliations

    • Corresponding Author InformationAddress correspondence to James P. Earls. MD. 5553 Rockpointe Drive, Clifton VA 20124

Fairfax Radiological Consultants PC, 2722 Merrilee Drive, Suite 230, Fairfax, VA 22031, USA

Received 3 September 2008; accepted 25 October 2008. published online 03 November 2008.

Abstract 

A prospective, electrocardiographically gated technique was recently adapted for use with coronary and cardiac multidetector row CT studies. The most widely available form of prospective gating uses “step-and-shoot” axial data acquisition, an incrementally moving table, adaptive electrocardiographic triggering, an improved image reconstruction algorithm, and multiphase reconstruction capability. Studies have shown a 77%–87% effective radiation dose reduction compared with retrospective gating and equal to significantly improved image quality. Comparison with conventional angiography has proven it to be as accurate as retrospective gating for coronary stenosis detection. The technique is not applicable to all patients because there are some restrictions for clinical use, including a limited number of reconstructed phases and a maximum scan heart rate of 68–75 beats/min. However, with careful patient selection and effective heart rate control, prospective gating can be used in a high percentage of cardiac CT examinations. This article reviews the scanning and patient selection protocols for prospective gating and discusses how it may be used in clinical practice.

KeyWords: Cardiac, Coronary, Computed tomography (CT), CT angiography, Prospective triggering

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Conflict of interest: Dr. Earls is a member of the speaker's bureau for GE Healthcare.

PII: S1934-5925(08)00631-X

doi:10.1016/j.jcct.2008.10.013

Journal of Cardiovascular Computed Tomography
Volume 3, Issue 1 , Pages 45-51, January 2009